Independent solar system planning

Off-Grid Solar Calculator

Plan a solar power system without relying on the electrical grid. Estimate your daily energy needs, solar panel array, battery bank, inverter and charge controller from the appliances you want to run.

✓ Appliance energy calculation ✓ Solar panel sizing ✓ Battery autonomy ✓ Inverter and controller estimates

Design Your Off-Grid Solar System

Enter the appliances you plan to use and the conditions your system must handle.

1. Daily appliance consumption

Enter the electrical input wattage, number of appliances, and average operating hours per day. Choose AC or DC for each appliance.

Appliance Watts Qty Hours/day Type
Tip: For refrigerators, freezers and pumps, use realistic average daily energy consumption or equivalent operating hours rather than assuming they run at full rated power all day.
2. Solar resource and array settings
Use the weakest month, not annual average sunshine.
Allows for temperature, wiring, dust and controller losses.
Use a value appropriate for the battery technology.
Used to estimate the number of panels.
Extra design allowance beyond the calculated minimum.
3. Battery bank specifications
Select a voltage supported by your equipment.
Days of operation without meaningful solar charging.
Follow the battery manufacturer's limits.
Accounts for energy lost during discharge.
Applied to AC appliance energy.
4. Inverter and controller settings
Estimate the AC appliances running together.
Does not replace motor surge calculations.
Preliminary current allowance only.
Reset

Your Off-Grid System Estimate

Recommended solar array
— kW
Your results will appear here

Enter your appliance loads and system conditions, then calculate your estimated off-grid system requirements.

Daily energy —
Battery capacity —
Inverter capacity —
Solar panel count —
Use the weakest-month peak sun hours for your location. A system sized using summer conditions may not provide sufficient energy during winter.

How to Size an Off-Grid Solar System

An off-grid solar system operates independently of the utility grid. It typically includes solar panels, a charge controller, a battery bank, an inverter and the required electrical protection equipment.

Unlike a grid-connected system, an off-grid installation must store enough energy to supply loads when solar production is insufficient. This makes daily consumption, seasonal sunlight and battery autonomy especially important.

1. Calculate daily energy consumption

For each appliance, multiply its electrical input wattage by the number of units and the hours it operates per day.

Daily energy (Wh) = Watts × Quantity × Hours per day Total daily energy = Sum of all appliance Wh/day

AC appliances use an inverter. The calculator therefore converts AC consumption into an estimated battery-side energy requirement using the entered inverter efficiency. DC appliances are counted directly.

2. Estimate the required solar panel array

The array must generate enough energy during the available peak sun hours to replace the energy used by the loads. The calculation also considers the selected system performance factor and battery charging efficiency.

Battery-side daily energy = AC Wh/day ÷ Inverter efficiency + DC Wh/day Minimum array (W) = Battery-side daily Wh ÷ (Peak sun hours × PV performance factor × Battery charge efficiency) Recommended array = Minimum array × (1 + Array margin / 100)

The final panel count is rounded up to the next whole panel. The actual installed array may therefore be slightly larger than the calculated requirement.

3. Calculate battery capacity

Battery capacity depends on daily battery-side energy, the number of days of autonomy, usable depth of discharge, and battery discharge efficiency.

Battery capacity (Wh) = Daily battery-side Wh × Autonomy days ÷ (Usable DoD × Discharge efficiency) Battery capacity (kWh) = Battery capacity (Wh) ÷ 1,000 Battery capacity (Ah) = Battery capacity (Wh) ÷ Battery bank voltage

4. Estimate inverter capacity

The inverter must supply the appliances expected to operate simultaneously. The calculator uses the larger of the entered simultaneous AC load and the sum of the AC appliance nameplate loads, then applies the selected margin.

Recommended inverter power = Design AC peak load × (1 + Inverter margin / 100)

This is only a preliminary continuous-power estimate. Motors, compressors and pumps may require substantially higher startup surge capacity.

5. Estimate charge controller current

Controller current (A) ≈ Installed array watts ÷ Battery voltage × (1 + Controller margin / 100)

This is a simplified estimate. The actual controller must also meet the PV string voltage, short-circuit current, maximum input power, charging voltage and battery compatibility requirements in its datasheet.

Example: Off-Grid Solar System for a Small Home

Consider a small off-grid property with a daily electricity requirement of 5 kWh.

  • Daily appliance energy: 5,000 Wh
  • Worst-month peak sun hours: 4 hours/day
  • PV performance factor: 80%
  • Battery charging efficiency: 95%
  • Battery autonomy: 2 days
  • Usable depth of discharge: 80%
  • Battery discharge efficiency: 95%
  • Battery bank voltage: 48 V
  • Panel rating: 450 W

Solar array estimate

5,000 ÷ (4 × 0.80 × 0.95) = 1,644.74 W

With a 20% additional array margin:

1,644.74 × 1.20 = 1,973.69 W

The approximate panel count is:

1,973.69 ÷ 450 = 4.39 → 5 panels

Battery bank estimate

5,000 × 2 ÷ (0.80 × 0.95) = 13,157.89 Wh

The required nominal battery bank is approximately 13.16 kWh.

13,157.89 ÷ 48 = 274.12 Ah

This example demonstrates the energy calculations. It does not establish that five panels will provide reliable year-round operation at a particular site. The actual design must be checked against seasonal solar production and battery charging requirements.

Important Design Factors for Off-Grid Systems

Use the weakest solar month

Solar availability changes throughout the year. A system that performs well during summer may have a substantial energy deficit in winter. Use local tilted-plane solar resource data for the weakest month that the system must cover.

Choose the correct battery chemistry

Lithium iron phosphate, lead-acid and other battery technologies have different usable discharge limits, charging requirements, temperature constraints and cycle-life characteristics. Enter the limits supplied by the battery manufacturer.

Check inverter surge capacity

A refrigerator, air conditioner, water pump or other motor-driven appliance may require a high starting current. Confirm that the inverter and battery management system can supply the required surge.

Check charge controller compatibility

Panel count alone does not determine whether a solar array can connect safely to an MPPT controller. Verify the cold-weather open-circuit voltage of each string and the controller's maximum PV input voltage and current.

Allow for future energy demand

Additional appliances, electric heating, cooking, water pumps and electric vehicles can significantly increase daily consumption. Include realistic future demand when planning the system.

Frequently Asked Questions

How many solar panels do I need for an off-grid house?

The required panel count depends on daily electricity consumption, worst-month peak sun hours, system losses, battery charging efficiency and panel wattage. Use the appliance table and solar resource inputs to estimate the required array.

How many batteries do I need to live off-grid?

First calculate the required battery bank energy in kWh. Then divide it by the usable energy capacity of the selected battery unit and round up. The batteries must also meet the required voltage, current and power ratings.

How many days of battery autonomy should I choose?

The appropriate autonomy period depends on weather, location, generator availability, reliability requirements and budget. Two days is a common preliminary planning assumption, but some systems need more or less. It should not be treated as a universal design standard.

Should I use 12 V, 24 V or 48 V?

Higher battery voltage reduces current for a given power level. Larger systems often benefit from higher-voltage battery architectures, but the inverter, charge controller, batteries and protection equipment must all be compatible.

Can I run an off-grid system without batteries?

Some systems operate directly from solar power during suitable sunlight conditions, but they cannot provide the same stored-energy backup after sunset or during low-production periods. A conventional stand-alone system generally requires energy storage or another reliable power source.

What are peak sun hours?

Peak sun hours represent the equivalent number of hours per day at an irradiance of 1,000 W/m². They are not the same as the number of daylight hours. Solar resource varies by location, season, panel orientation and shading.

Does this calculator guarantee year-round off-grid operation?

No. It provides a preliminary energy-based estimate. A detailed design should model monthly solar production, consecutive cloudy periods, battery charging limits, load peaks, temperature and equipment specifications.

Related Solar Calculators

Explore other tools to plan individual components of a solar power installation.

Disclaimer and Electrical Safety

This calculator provides preliminary estimates for educational and planning purposes. It does not replace a professional off-grid solar system design.

The estimated inverter and charge controller ratings are not equipment approvals. Actual equipment selection must consider continuous and surge power, PV open-circuit voltage, short-circuit current, MPPT operating range, battery maximum charge and discharge current, cable ratings, overcurrent protection, grounding and manufacturer requirements.

Battery performance changes with temperature, age, discharge rate and operating conditions. Solar production changes with weather, shading, orientation, tilt and season. A detailed design should use site-specific resource data and suitable engineering calculations.

Consult a qualified solar and electrical professional before purchasing, installing or modifying an off-grid electrical system. Follow applicable local regulations and all equipment manufacturers' instructions.