Enter Your Battery and Load Details
Use the battery's rated capacity and the actual power consumption of the connected equipment.
Battery Runtime Results
Enter your battery capacity, charge level, efficiency, and connected load. Then select Calculate Battery Backup Time.
How Does the Battery Backup Time Calculator Work?
Battery backup time is the estimated period that a battery can supply power to connected electrical equipment before reaching its minimum permitted state of charge.
The calculation depends on the battery's energy capacity, current charge level, reserve setting, battery discharge efficiency, inverter efficiency where applicable, and the power consumed by the connected load.
Step 1: Calculate nominal battery energy
If the battery capacity is entered in kilowatt-hours, that value is used directly.
Nominal battery energy (kWh) = Entered battery capacity (kWh)If capacity is entered in amp-hours, it is converted using the battery bank voltage.
Battery energy (Wh) = Battery voltage (V) × Capacity (Ah) Battery energy (kWh) = Voltage × Ah ÷ 1,000Step 2: Calculate the available state-of-charge window
The calculator considers the difference between the current state of charge and the minimum reserve.
Available SOC (%) = Current SOC (%) − Minimum reserve (%) Energy before losses = Nominal battery energy × Available SOC / 100Step 3: Account for battery discharge efficiency
Not all stored battery energy reaches the battery terminals as usable electrical energy. Discharge efficiency accounts for energy lost during the battery discharge process.
Energy after battery losses = Energy before losses × Battery efficiencyStep 4: Account for inverter efficiency
AC equipment normally receives power through an inverter. The inverter converts DC battery power into AC power and consumes some energy in the process.
AC energy delivered = Energy after battery losses × Inverter efficiencyFor a direct DC load, the calculator does not apply inverter losses.
Step 5: Calculate estimated runtime
Backup time (hours) = Energy delivered (kWh) × 1,000 ÷ Load power (W)Example: How Long Will a 10 kWh Battery Last?
Consider a home battery with the following specifications and operating conditions:
- Nominal battery capacity: 10 kWh
- Current state of charge: 100%
- Minimum reserve: 20%
- Battery discharge efficiency: 95%
- Inverter efficiency: 92%
- Connected AC load: 1,000 W
First, calculate the available state-of-charge window:
Available SOC = 100% − 20% = 80%Calculate the energy available before losses:
10 kWh × 0.80 = 8 kWhApply battery discharge efficiency:
8 kWh × 0.95 = 7.6 kWhApply inverter efficiency:
7.6 kWh × 0.92 = 6.992 kWhFinally, calculate runtime:
6.992 × 1,000 ÷ 1,000 = 6.992 hoursThe estimated backup time is approximately 6 hours and 59 minutes, assuming the load remains constant.
What Affects Battery Backup Time?
Battery capacity
A larger battery generally provides more stored energy and longer backup time, assuming the same load and operating conditions.
Electrical load
The higher the power consumption of connected appliances, the faster the battery will discharge. A 2,000 W load generally uses energy twice as quickly as a 1,000 W load.
Depth of discharge and reserve
A battery reserve setting protects a portion of the stored energy from being used. Increasing the reserve reduces the energy available for backup.
Battery efficiency
Battery chemistry, temperature, discharge rate, age, and operating conditions affect the energy that can be delivered during discharge.
Inverter efficiency
For AC appliances, inverter losses reduce the energy delivered to the load. The actual efficiency depends on the inverter and its operating load.
Surge power and startup current
Some appliances, including refrigerators, pumps, and compressors, draw more power when starting than during normal operation. A battery may have sufficient stored energy but still be unable to supply the required instantaneous power.
Battery Backup Time for Common Loads
The following examples illustrate how load size affects runtime. They assume 6.992 kWh of energy is delivered to the load, as in the worked example above.
| Example load | Power consumption | Estimated runtime |
|---|---|---|
| LED lighting | 100 W | 69.92 hours |
| Desktop computer | 300 W | 23.31 hours |
| Refrigerator (average load) | 200 W | 34.96 hours |
| Television and electronics | 250 W | 27.97 hours |
| Small household load | 500 W | 13.98 hours |
| Home backup load | 1,000 W | 6.99 hours |
| High household load | 2,000 W | 3.50 hours |
| Large electrical load | 3,000 W | 2.33 hours |
These are simplified constant-load examples, not appliance-specific predictions. Real appliances may cycle on and off or have changing power consumption.
Frequently Asked Questions
How long will a 5 kWh battery last?
Runtime depends on the usable energy and connected load. For example, if 80% of a 5 kWh battery is available and the combined battery and inverter efficiency is 87.4%, approximately 3.496 kWh reaches an AC load. A constant 1,000 W load would run for approximately 3.5 hours.
How long will a 10 kWh battery power a house?
It depends on the household's actual power consumption. A 10 kWh battery can provide considerably longer backup for essential low-power appliances than for an entire house with heating, cooking, and other high-power equipment.
How do I calculate battery runtime from Ah?
Multiply the battery voltage by its amp-hour capacity to obtain watt-hours. Divide by 1,000 to convert watt-hours into kilowatt-hours. Then account for usable state of charge, efficiency, and load power.
Should I include inverter efficiency?
Yes, if the connected equipment uses AC power through an inverter. For a direct DC load, inverter efficiency should not be applied.
What is a battery reserve?
A battery reserve is the portion of stored energy that is intentionally kept unused. It can help protect the battery and preserve emergency backup capacity, depending on the battery manufacturer's recommendations and system settings.
Does a larger battery always provide more backup time?
A larger battery generally stores more energy, but runtime also depends on load power, usable capacity, temperature, battery condition, and conversion losses.
Can I use this calculator for lithium and lead-acid batteries?
Yes, as a simplified energy estimate. However, the usable state-of-charge range, discharge efficiency, voltage behavior, and discharge limits differ between battery technologies. Use the specifications for your particular battery.
Does this calculator account for solar panel charging?
No. This calculator estimates runtime without adding energy from solar panels or another charging source. Solar generation during an outage can extend backup time, but requires a separate generation and energy balance calculation.
Related Solar and Battery Calculators
Explore other tools for planning your solar and battery backup system:
Calculation Limitations and Safety
This calculator provides a simplified estimate based on constant load power and entered battery specifications. Actual runtime can differ because of temperature, battery age, discharge rate, voltage drop, inverter behavior, and battery management system limits.
The calculation does not verify whether a battery, inverter, fuse, cable, or other component can safely support the connected load. Check continuous and surge power ratings, maximum discharge current, minimum operating voltage, and manufacturer requirements.
Battery capacity in kWh should represent nominal energy unless you deliberately enter a manufacturer's usable capacity. If the capacity is already specified as usable energy, do not apply an additional usable-capacity reduction without understanding how the manufacturer defines that rating.
Always follow the battery and inverter manufacturer's installation instructions and applicable electrical regulations. Have fixed battery systems installed or reviewed by a qualified professional.